Alfa+ Solar PCU 1kVA/24V

Alfa+ Solar PCU 1kVA/24V that is mainly used in Hospitals, schools, industries petrol pumps, banks and also in home. It continuously monitor battery and solar voltage as well as grid and output voltage with their current. PCU (Power Conditioning Unit) is an integrated unit consists of grid charger, inverter, MPPT Solar Charger. It continuously monitors Battery and Solar voltage as well as Grid and Output voltage with their currents.

MPPT based solar charger extracts the maximum power from the solar panels whereby it increases the efficiency of the system. MPPT charger has multistage charging which maintains the battery charging voltage such that it increases the lifespan of battery.

Alfa+ Solar PCU 1kVA/24V

Alfa+ Solar PCU 1kVA/24V that is mainly used in Hospitals, schools, industries petrol pumps, banks and also in home. It continuously monitor battery and solar voltage as well as grid and output voltage with their current.

UTL rMPPT Solar PCU will generate up to 30% more electricity and also will show it Everyday till 31 March 2025.

PCU (Power Conditioning Unit) is an integrated unit that consists of a grid charger, inverter, MPPT Solar Charger. It continuously monitors Battery and Solar voltage as well as Grid and Output voltage with their currents. MPPT based Solar charger extracts the maximum power from the solar panels whereby it increases the efficiency of the system. MPPT charger has multistage charging which maintains the battery charging voltage such that it increases the lifespan of the battery.

Alfa+ Solar PCU 1kVA/24V is a Model of Power Conditioning Unit (PCU) which uses Solar (primary) and Grid (secondary), to charge the batteries. Since the usage of power from the grid is secondary, grid power is only used when solar energy is not present and the battery voltage level reduces to 11.5V/Battery (Default 11.5V, Configurable).
Grid power is also needed when solar power generation is less and the battery voltage is reduced to 11.5V/Battery (Default 11.5V, Configurable)

  • Battery selection mode
  • Operating Mode Selection
  • LCD display with Energy Meter and Data Logging (optional)
  • Pure sine wave
  • User-configurable by LCD

Battery selection mode

In UTL’s Alfa PCU you have a great feature that is battery selection mode by this we can select any type of battery as per requirement i.e Flat plate/Tubular/SMF/Lead-acid Battery and can set charging voltage and charging current as per requirement.

Operating Mode Selection

  • PCU Mode – Priority Solar →Battery → Grid
  • Smart Mode -Priority Solar → Grid → Battery
  • Hybrid Mode – Priority for load Grid →Solar →Battery, Priority for battery charging Solar → Grid

LCD display with Energy Meter and Data Logging (optional)

UTL PCU is also available with LCD. This is an optional feature that can be availed by the customer for the better user interface. When the customer opts for this feature, an Energy Meter and Data Logging facilities are also provided to the customer, which help the user to access information about the present and past status of the PCU functionality. In this way, the user can easily track the past records of the unit and thus he/she can have an idea about what needs to be done for better results.

Pure sine wave

The output of the UTL’s Alfa PCU is a pure sine wave. and it operates your appliances friendly.

User-configurable by LCD

User-friendly calibration settings:-

You can change the below settings of Alfa PCU by itself like,
Configurable Grid Reconnect setting
Configurable Battery Low cut setting
Configurable Grid low cut/High cut setting

User-friendly operational settings:-

No-load shut down Enable/Disable.
Grid charger Enable/Disable.
IT Load Enable/Disable.
Input AC source Grid/Genset.

Technical Information

<td colspan="8">88

Perameters Units Ratting
System Rating KVA 1 1 2 3 5 5 7.5 7.5 10 10 15
Operating DC Voltage V 24 48 48 48 48 48 96 120 120 180 240
Photovoltaic Input
Input Voltage Range (Min-Max) VDC 45-90 80-230 160-450 200-550 300-625 400-750
Maximum PV Power Recommended KW 1.0 1.0 2.0 3.0 5.0 7.5 10 15
Solar Charge Controller Rating A 40 20 40 60 100 50 75 60 80 50 60
MPPT Based Charging Controller
Switching Element Mosfed IGBT
Controller DSP
Type of Charger MTTP
Efficiency 95
Parameter
Battery Low Buzzer V Batt. Low Out +0.2 11.2
Battery Low Cut V 10-11.7 11
Battory High Cut (INV.) V SPV Present-SPV CHG. REF +1V for 15 Sec, SPV CHG. REF +1.5V for 2Sec 16
SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec 14.7
Battery Charging Voltage by SPV V 13.5-16 14.5
Battery Charging Current by SPV A 12-60 18
Battery Charging Voltage by Gad V 13.0-15 14.2
Battery Charging Current by Grid A 6-15 10
Grid Low Cut Voltage (IT Mode/Mormal) V NA120-200 175/120
Grid High Cut Voltage (IT Mocie/Noemal) V NA 245-280 260/280
Grid Charging Enable/Disable Enable
IT Load Enable/Disable Diable
Operating Mode Smart PCU Hybrid Smart
Output Voltage Low V 170-190 185
Output Voltage Mic V 250-260 260
No Load Shut Down Enable/Disable Diable
Input Source Grid/Genset Grid
Battery
Grid Disconnect (Solar Available) PCU/SMART <td colspan="11"@14.5/Battery for 2minutes or 13.5/Battery-100% Current
Grid Reconnect (PCU Mode/Smart Mode) V 11-12 11.5
Temp. Compensation <td colspan="11"@3mVlcall"C ; 18mVlBattery/°C
Inverter
Switching Element Mosfed IGBT Mosfed IGBT
Control PWM
Nominal Output Voltage VAC 220
Output Supply Phase 1Phase, 3Wire
Output Waveform Pure Sine Wave
Nominal Frequency Hz 50.0
Load Current A 4.5 5 9 14 18 18 27 27 36 36 54
Voltage Regulation 1
Output Voltage Distortion with 100% Linear Load <td colspan="11"<3
Overload Capacity (IT LOAD DISABLE) 100-120(2time auto reset) : 60sec
120-150(2time auto reset) : 30sec
150-200 : 2sec
200-300 : 1sec
300-400 : 250ms
>400 : 20ms
Overload Capacity (IT LOAD ENABLE) 100-110 : 10 Min
110-120 : 2 Min
120-150 : 30sec
150-200 : 2sec
200-300 : 1sec
300-400 : 250ms
>400 : 20ms
Peak Efficiency <td colspan="3">82
Noise @ 1meler dB 50
Cooling Temp Controlled, Fan
Protections Overload, Battery Low Battery High Output Low, Output High Output Short Ckt. Overheat,
Under Frequency Over Frequency, Solar Panel Reverse
Display Parameters Battery Vitage Charging current Discharging current Charging KWH Discharging KWH, Solar Vortage Solar Current instantaneous Power Curative Power Grid Voltage Grid Current Grid Frequency
Output Voltage Output Current Output Frequency NLSD EnOn IT Load En On Grid Charger En On Operating Mode PCU/SMT/HYD
Switches Reset for System ON OFF. UP, DOWN, BACK ENTER (for LCD Configuration)
Indications System ON, Inverter ON SPV Charging Grd Charging Battery Low High Overload, Overheat, Mains Low
Mains High Under Frequency. Over Frequency. NLSD. Fault
Environment
Operating Temperature C 0-50
Max Relative Humidity @25°C (non condensing) % 95
Degree of Protection IP21
Data Loggin 30 Day Data Storage
Dimension (LxWxH) Inch 18 X 10 X 18 24 X 13 X 23 24 X 13 X 26
Weight (Approx) Kg. 32 33 40 44 50 71 65 80 103 120