RSK Solar Energy

r-MPPT Solar Management Unit 12V/24V 40A

UTL Solar

r-MPPT Solar Management Unit (SMU) 12V/24V 40A can convert your simple Inverter into Solar Inverter. SMU ensures priority usage of Solar Power to reduce Grid consumption.

r-MPPT Solar Management Unit 12V/24V 40A, UTL Solar

Specifications

General
SMU Capacity SMU1224/40
Operating Temperature 0°C to 50°C
Storage Temperature -20° C to 60°C
Battery Type Tubular/SMF, Battery 12V/24V
Battery Capacity AH 100AH – 180AH
Battery charging regulation method Bulk, Absorption, Float, Equalise
Electrical
Nominal System Voltage 12/24 DC
Charging Current (Solar) 20A-40A
Charge Controller Efficiency >95%
Idle Consumption <20mA
Operating Solar Input Voltage (VOC) 22.5V/45V
Max. Solar Input Voltage (VOC) 25A/45V
Min Solar Input Voltage (VOC) 15V/30V ± 2%
Solar Panel Recovery Voltage 17V/31V ± 2%
Max. Solar Current 40A
Efficiency >95%
Battery Set Point @25 °C
Absorption voltage Tubular Battery 14.2V/28.4V±2%
Absorption voltage SMF Battery 13.7V/27.4V±2%
Absorption Duration 3hr
Float Voltage Tubular Battery 14V/28±2%
Float Voltage SMF Battery 13.7V/27.0V±2%
Bulk Voltage Tubular Battery 14.6V/29.2V±2%
Equalise Voltage 14.9/29.8V±2%
Equalise Duration 3hr
Equalise Calendar 28days
Mains reconnect when Solar not Present At any Battery Voltage
Mains reconnect when insufficient solar power = 11.8V/23.6V ± 2%
Mains disconnect when sufficient solar power for Tubular = 13.8V/27.6V ± 2%
Mains disconnect when sufficient solar power for SMF 13.7V/27.4V ± 2%
Physical
Fixing Wall Mounted
Weight 1.5Kg
Ingress Protection IP-20
Dimension 228X152X76 mm

As published by UTL Solar. We confirm figures that matter for your design against the current datasheet before you order.

About this product

The SMU could charge battery automatically from photovoltaic (PV) systems. The charging process has been optimized for long battery life and improved system performance. The comprehensive self-diagnostics and extensive electronic protection can prevent damage against incorrect wiring or system faults. The system can work as a domestic inverter and a solar inverter automatically or manually through a switch except in night condition. In night condition the system will work as normal domestic inverter. The charging process has been optimized for long battery life and improved system performance. The comprehensive self-diagnostics and extensive electronic protection can prevent damage against incorrect wiring or system faults.

If the sunlight is full then solar charge controller charge the solar battery with the first priority of solar energy, when the battery is fully charged, it runs the load from the solar and automatically starts running the load on the power back in the evening. Solar management unit gives first priority to solar panel’s power.